8.7/15 kV CU/XLPE/AWA/PVC Single-Core MV Cables

8.7/15 kV single-core medium voltage cables with copper conductors, XLPE insulation and aluminium wire armour (AWA) for fixed power distribution requiring mechanical protection.

8.7 15 kV CU XLPE AWA PVC Single-Core MV Cables

Product Overview

Our 8.7/15 kV CU/XLPE/AWA/PVC cables combine a screened copper conductor with aluminium wire armour (AWA) in a single-core medium voltage construction.

AWA provides mechanical protection without using magnetic steel armour around the single core. XLPE insulation supports medium voltage operation, while the PVC outer sheath protects the completed cable during installation and service.

Conductor size, metallic screen design and installation arrangement should be selected according to the project cable schedule. Send us your technical specification so we can confirm the required construction before quotation.

Applications

These single-core AWA cables are suitable for fixed medium voltage installations where mechanical protection is required.

utility power distribution network with medium voltage cable installation

Substation Connections

For cable runs between transformers, switchgear and medium voltage distribution equipment.

low-voltage-power-distribution-using-PVC-power-cables_720x440

Industrial Power Networks

For fixed power routes serving factories, processing plants and large electrical loads.

commercial and residential wiring projects with PVC cables

Infrastructure Projects

For utility and infrastructure projects using single-core medium voltage cable arrangements.

underground and outdoor power distribution cable installation

Underground Cable Routes

For suitable trenches, ducts and buried routes, subject to the approved installation design.

CHARACTERISTICS

Voltage Rating Uo/U

U₀/U: 8.7/15 kV for medium voltage power distribution.

Temperature Rating

XLPE insulation supports a maximum continuous conductor operating temperature of 90°C, subject to the approved cable design.

Short-Circuit Temperature

250°C, maximum 5 seconds

Metallic Screening

Screening layers are included around the insulated cores as part of the medium voltage construction.

industrial electrical installation using PVC insulated cables

Cable Construction

The cable consists of a stranded aluminum conductor, XLPE insulation and a PVC outer sheath. Construction details can be adjusted according to project specifications and applicable standards.

Item Description
Conductor
Stranded copper conductor, Class 2
Conductor Screen
Extruded semi-conductive layer
Insulation
XLPE ( Cross-linked polyethylene compound )
Insulation Screen
Extruded semi-conductive layer
Metallic Screen
Copper wire or copper tape, subject to the approved design
Armour
Galvanized steel wire armour (SWA)
Inner Bedding
PVC compound or specified suitable compound
Outer Sheath
PVC (Polyvinyl Chloride)

Reference Standards    IEC 60502-2 and IEC 60228, or specified project standards

Cable Sizes & Technical Parameters

No. of Cores Nominal Cross-sectional Area (mm²) Conductor Type Nominal Overall Diameter (mm) Nominal Weight (kg/km)
1
50
Stranded, Class 2
29
1400
1
70
Stranded, Class 2
31
1710
1
95
Stranded, Class 2
35
2110
1
120
Stranded, Class 2
36
2360
1
150
Stranded, Class 2
38
2710
1
185
Stranded, Class 2
39
3210
1
240
Stranded, Class 2
42
3760
1
300
Stranded, Class 2
45
4610
1
400
Stranded, Class 2
48
5510
1
500
Stranded, Class 2
51
6750
1
630
Stranded, Class 2
56
8200

Class 2 Stranded Copper Conductors for 8.7/15 kV Cu XLPE SWA PVC Power Cable

Nominal Size Conductor Structure MAX. DC CONDUCTOR RESISTANCE AT 20°C
— PLAIN ANNEALED COPPER (Ω/km)
50
Stranded, Class 2
0.387
70
Stranded, Class 2
0.268
95
Stranded, Class 2
0.193
120
Stranded, Class 2
0.153
150
Stranded, Class 2
0.124
185
Stranded, Class 2
0.0991
240
Stranded, Class 2
0.0754
300
Stranded, Class 2
0.0601
400
Stranded, Class 2
0.047

The above table is in accordance with IEC 60228

Why Choose Vastcore Cable

Project-Based Cable Configuration

We review conductor size, screen requirements, SWA construction and installation conditions against your cable schedule.

Clear Technical Communication

We check drawings and specifications before quotation so the proposed construction matches the project requirements.

Inspection and Documentation

Applicable test reports, inspection records, packing details and shipping documents can be prepared according to order requirements.

START YOUR PROJECT

Ready to Discuss Your Single-Core MV Cable Requirements?

Send us your cable schedule, conductor size, screen requirements, quantity and destination. Our team will review the details and prepare the next step for quotation.