0.6/1 kV CU/XLPE/AWA/PVC Single-Core Cables

Copper conductor single-core power cables with XLPE insulation, non-magnetic aluminium wire armour (AWA) and a PVC outer sheath for fixed low-voltage power distribution.

AWA provides mechanical protection without introducing the magnetic effects associated with steel wire armour around single-core AC cables.

0.6/1 kV CU/XLPE/AWA/PVC Single-Core Cables

Product Overview

Our 0.6/1 kV CU/XLPE/AWA/PVC single-core cables are designed for fixed power transmission and distribution systems that require mechanical protection and a single-core cable construction.

Non-magnetic aluminium wire armour (AWA) is used instead of steel wire armour around the single-core cable. It helps minimise magnetic losses and unwanted heating while providing protection against mechanical impact and installation stresses.

We can supply 0.6/1KV Cu/XLPE/AWA/PVC single-core cables in different conductor sizes, sheath colours and cable lengths according to project specifications, installation arrangements and applicable standards.

Applications

0.6/1 kV CU/XLPE/AWA/PVC cables are suitable for fixed single-core power circuits where additional mechanical protection is required. Their non-magnetic AWA construction makes them suitable for AC installations where steel wire armour should not be used around individual single-core cables.

utility power distribution network with medium voltage cable installation

Industrial Facilities

For factories, processing plants, electrical equipment and industrial power distribution circuits.

low-voltage-power-distribution-using-PVC-power-cables_720x440

Utility Distribution

For low-voltage distribution networks, substations and fixed utility power systems.

commercial and residential wiring projects with PVC cables

Infrastructure Projects

For transport facilities, public utilities and infrastructure networks requiring protected single-core power cables.

underground and outdoor power distribution cable installation

Underground Installation

For cable trenches, underground ducts and direct burial where permitted by the applicable installation requirements.

CHARACTERISTICS

Voltage Rating Uo/U

U₀/U: 0.6/1 kV for fixed low-voltage power transmission and distribution systems.

Temperature Rating

90°C , maximum long-term permissible conductor temperature of during normal operation.

Short-Circuit Temperature

250°C, maximum 5 seconds

Mechanical Protection

Aluminium wire armour provides mechanical protection while helping minimise magnetic losses in single-core AC cable installations.

Minimum Bending Radius

Minimum bending radius and installation requirements should be confirmed according to the cable diameter, construction and applicable project standard.

industrial electrical installation using PVC insulated cables

Cable Construction

The cable consists of a stranded aluminum conductor, XLPE insulation and a PVC outer sheath. Construction details can be adjusted according to project specifications and applicable standards.

Item Description
Conductor
Stranded copper conductor, Class 2 according to IEC 60228
Insulation
XLPE ( Cross-linked polyethylene compound )
Inner Covering
Extruded PVC bedding or suitable separation layer
Armour
Non-magnetic aluminium wire armour (AWA)
Outer Sheath
PVC (Polyvinyl Chloride)

Reference Standards:IEC 60502-1 and IEC 60228, or specified project standards.

Cable Sizes & Technical Parameters

No. of Cores Nominal Cross-sectional Area (mm²) Conductor Type Nominal Overall Diameter (mm) Nominal Weight (kg/km)
1
50
Stranded, Class 2
19.3
764
1
70
Stranded, Class 2
21.3
991
1
95
Stranded, Class 2
23.4
1280
1
120
Stranded, Class 2
25.4
1553
1
150
Stranded, Class 2
27.5
1872
1
185
Stranded, Class 2
29.9
2242
1
240
Stranded, Class 2
32.7
2865
1
300
Stranded, Class 2
35.8
3511
1
400
Stranded, Class 2
40.7
4510

Class 2 Stranded Copper Conductors for 0.6/1 kV Cu XLPE AWA PVC Power Cable

Nominal Size Conductor Structure MAX. DC CONDUCTOR RESISTANCE AT 20°C — PLAIN ANNEALED COPPER (Ω/km)
50
Stranded, Class 2
0.387
70
Stranded, Class 2
0.268
95
Stranded, Class 2
0.193
120
Stranded, Class 2
0.153
150
Stranded, Class 2
0.124
185
Stranded, Class 2
0.0991
240
Stranded, Class 2
0.0754
300
Stranded, Class 2
0.0601
400
Stranded, Class 2
0.047

The above table is in accordance with IEC 60228

Why Choose Vastcore Cable

Project-Based AWA Configuration

Conductor size, armour construction, sheath colour and cable length can be selected according to circuit design and installation conditions.

Clear Technical Communication

We review the required cable size, single-core arrangement, operating conditions and applicable standards before quotation and production coordination.

Inspection and Documentation

Applicable test reports, inspection records, cable drum details, packing information and shipping documents can be prepared according to order requirements.

START YOUR PROJECT

Ready to Discuss Your AWA Cable Requirements?

Send us the required conductor size, cable length or quantity, installation arrangement, applicable standard and destination. Our team will review the specifications and prepare a quotation for the required AWA single-core cable.