8.7/15 kV CU/XLPE/PVC Medium Voltage Cables

8.7/15 kV Copper conductor medium voltage cables with XLPE insulation, a metallic screen and a PVC outer sheath for fixed power distribution installations.

8.7 15 kV CU XLPE PVC medium voltage cables

Product Overview

Our 8.7/15 kV CU/XLPE/PVC medium voltage cables are designed for fixed power distribution in utility, industrial and infrastructure networks.

The copper conductors are insulated with XLPE and combined with conductor, insulation and metallic screening layers. These layers form an important part of the cable’s electrical design at medium voltage. A PVC outer sheath provides external protection for the completed cable.

Conductor size, cable configuration and metallic screen construction should be selected according to the network design, installation method and project specification. Share your required cable schedule or technical drawing with us so we can confirm a suitable construction before quotation.

Applications

8.7/15 kV CU/XLPE/PVC cables are used in fixed medium voltage installations where the cable route provides appropriate mechanical protection.

utility power distribution network with medium voltage cable installation

Substations and Switchgear

For cable connections between transformers, switchgear and distribution equipment.

low-voltage-power-distribution-using-PVC-power-cables_720x440

Industrial Facilities

For power supply within factories, processing plants and other industrial sites.

commercial and residential wiring projects with PVC cables

Power Distribution Networks

For medium voltage distribution routes connecting substations, transformers and electrical loads.

underground and outdoor power distribution cable installation

Infrastructure Projects

For utility and infrastructure installations using cable ducts, trays or other suitable protected routes.

CHARACTERISTICS

Voltage Rating Uo/U

U₀/U: 8.7/15 kV for medium voltage power distribution systems.

Temperature Rating

XLPE insulation supports a maximum continuous conductor operating temperature of 90°C, subject to the specified cable design.

Short-Circuit Temperature

250°C, maximum 5 seconds

industrial electrical installation using PVC insulated cables

Cable Construction

The cable consists of a stranded aluminum conductor, XLPE insulation and a PVC outer sheath. Construction details can be adjusted according to project specifications and applicable standards.

Item Description
Conductor
Stranded copper conductor, Class 2
Conductor Screen
Extruded semi-conductive layer
Insulation
XLPE ( Cross-linked polyethylene compound )
Insulation Screen
Extruded semi-conductive layer
Metallic Screen
Copper wire or copper tape, subject to the approved design
Filler
PP yarn
Outer Sheath
PVC (Polyvinyl Chloride)

Reference Standards    IEC 60502-2 and IEC 60228, or specified project standards

Cable Sizes & Technical Parameters

No. of Cores Nominal Cross-sectional Area (mm²) Conductor Type Nominal Overall Diameter (mm) Nominal Weight (kg/km)
1
50
Stranded, Class 2
25
984
1
70
Stranded, Class 2
27
1201
1
95
Stranded, Class 2
29
1490
1
120
Stranded, Class 2
30
1765
1
150
Stranded, Class 2
32
2091
1
185
Stranded, Class 2
34
2452
1
240
Stranded, Class 2
36
3034
1
300
Stranded, Class 2
42
3672
1
400
Stranded, Class 2
45
4646
1
500
Stranded, Class 2
50
5651
1
630
Stranded, Class 2
55
7154
No. of Cores Nominal Cross-sectional Area (mm²) Conductor Type Nominal Overall Diameter (mm) Nominal Weight (kg/km)
3
50
Stranded, Class 2
55
3529
3
70
Stranded, Class 2
58
4197
3
95
Stranded, Class 2
63
5230
3
120
Stranded, Class 2
66
6120
3
150
Stranded, Class 2
70
7207
3
185
Stranded, Class 2
74
8378
3
240
Stranded, Class 2
79
10177
3
300
Stranded, Class 2
84
12159
3
400
Stranded, Class 2
89
15641

Class 2 Stranded Copper Conductors for 8.7/15 kV Cu XLPE PVC Power Cable

Nominal Size Conductor Structure MAX. DC CONDUCTOR RESISTANCE AT 20°C — PLAIN ANNEALED COPPER (Ω/km)
50
Stranded, Class 2
0.387
70
Stranded, Class 2
0.268
95
Stranded, Class 2
0.193
120
Stranded, Class 2
0.153
150
Stranded, Class 2
0.124
185
Stranded, Class 2
0.0991
240
Stranded, Class 2
0.0754
300
Stranded, Class 2
0.0601
400
Stranded, Class 2
0.047

The above table is in accordance with IEC 60228

Cable Sizes & Technical Parameters

No. of Cores Nominal Cross-sectional Area (mm²) Conductor Type Nominal Overall Diameter (mm) Nominal Weight (kg/km)
3
50
Stranded, Class 2
57
5500
3
70
Stranded, Class 2
61
6500
3
95
Stranded, Class 2
65
7600
3
120
Stranded, Class 2
68
8600
3
150
Stranded, Class 2
74
10500
3
185
Stranded, Class 2
77
11900
3
240
Stranded, Class 2
83
14200
3
300
Stranded, Class 2
88
16600
3
400
Stranded, Class 2
95
19700

Class 2 Stranded Copper Conductors for 8.7/15 kV Cu XLPE SWA PVC Power Cable

Nominal Size Conductor Structure MAX. DC CONDUCTOR RESISTANCE AT 20°C
— PLAIN ANNEALED COPPER (Ω/km)
50
Stranded, Class 2
0.387
70
Stranded, Class 2
0.268
95
Stranded, Class 2
0.193
120
Stranded, Class 2
0.153
150
Stranded, Class 2
0.124
185
Stranded, Class 2
0.0991
240
Stranded, Class 2
0.0754
300
Stranded, Class 2
0.0601
400
Stranded, Class 2
0.047

The above table is in accordance with IEC 60228

Why Choose Vastcore Cable

Project-Based Cable Configuration

We review conductor size, cable arrangement, screen requirements and installation conditions against your project specifications.

Clear Technical Communication

Cable schedules and technical drawings help us confirm the required construction before quotation and production coordination.

Inspection and Documentation

Applicable test reports, inspection records, packing details and shipping documents can be prepared according to order requirements.