0.6/1 kV CU XLPE SWA PVC Armoured Cables

0.6/1 kV copper conductor armoured power cables with XLPE insulation, galvanized steel wire armour and a PVC outer sheath for fixed low-voltage power distribution.

XLPE Armoured Cable

Product Overview

Our 0.6/1 kV CU/XLPE/SWA/PVC armoured cables are designed for fixed power transmission and distribution where additional mechanical protection is required.

Galvanized steel wire armour (SWA) helps protect the cable against mechanical impact, external pressure and installation stresses. The stranded copper conductors provide reliable electrical conductivity. The XLPE insulation supports a maximum continuous conductor operating temperature of 90°C.

We can supply 0.6/1 kV CU/XLPE/SWA/PVC in multicore configurations with different conductor sizes and core identification options. You can select cable construction according to your installation conditions, project specifications and applicable standards.

Applications

0.6/1 kV CU/XLPE/SWA/PVC armoured cables are suitable for fixed installations in industrial, commercial and infrastructure power systems. Their steel wire armour (SWA) makes them suitable for locations where unarmoured cables may not provide sufficient mechanical protection.

utility power distribution network with medium voltage cable installation

Industrial Facilities

For factories, workshops, processing plants and fixed electrical equipment.

low-voltage-power-distribution-using-PVC-power-cables_720x440

Power Distribution

For low-voltage distribution networks, substations and utility systems.

commercial and residential wiring projects with PVC cables

Infrastructure Projects

For transport facilities, public utilities and infrastructure power networks.

underground and outdoor power distribution cable installation

Underground Installation

For cable trenches, protected direct burial and underground distribution routes.

CHARACTERISTICS

Voltage Rating Uo/U

0.6/1 kV

Temperature Rating

90°C , maximum long-term permissible conductor temperature of during normal operation.

Short-Circuit Temperature

250°C, maximum 5 seconds

Mechanical Protection

Galvanized steel wire armour (SWA) provides protection against impact and external mechanical loads.

Minimum Bending Radius

Minimum bending radius and installation requirements should be confirmed according to the cable diameter, construction and applicable project standard.

industrial electrical installation using PVC insulated cables

Cable Construction

The cable consists of a stranded aluminum conductor, XLPE insulation and a PVC outer sheath. Construction details can be adjusted according to project specifications and applicable standards.

Item Description
Conductor
Stranded copper conductor, Class 2 according to IEC 60228
Insulation
XLPE ( Cross-linked polyethylene compound )
Filler
Non-hygroscopic filler where required
Inner Covering
Extruded PVC compound
Armour
Galvanized steel wire armour (SWA)
Outer Sheath
PVC (Polyvinyl Chloride)

Core Identification Colours or numbering according to the applicable standard

Cable Sizes & Technical Parameters

No. of Cores Nominal Cross-sectional Area (mm²) Conductor Type Nominal Overall Diameter (mm) Nominal Weight (kg/km)
2
1.5
Stranded, Class 2
12.1
302
2
2.5
Stranded, Class 2
13.6
346
2
4
Stranded, Class 2
14.7
410
2
6
Stranded, Class 2
15.9
499
2
10
Stranded, Class 2
18.0
648
2
16
Stranded, Class 2
20.4
978
2
25
Stranded, Class 2
20.4
1290
2
35
Stranded, Class 2
23.3
1500
2
50
Stranded, Class 2
25.8
1890
2
70
Stranded, Class 2
29
2450
2
95
Stranded, Class 2
33.1
3300
2
120
Stranded, Class 2
36.1
4020
2
150
Stranded, Class 2
39.3
4750
2
185
Stranded, Class 2
50.7
600
2
240
Stranded, Class 2
57.5
7622
2
300
Stranded, Class 2
61.3
9041
2
400
Stranded, Class 2
68
11009
No. of Cores Nominal Cross-sectional Area (mm²) Conductor Type Nominal Overall Diameter (mm) Nominal Weight (kg/km)
3
1.5
Stranded, Class 2
12.6
330
3
2.5
Stranded, Class 2
14.1
390
3
4
Stranded, Class 2
15.3
464
3
6
Stranded, Class 2
16.6
568
3
10
Stranded, Class 2
19.5
866
3
16
Stranded, Class 2
21.6
1152
3
25
Stranded, Class 2
23.6
1800
3
35
Stranded, Class 2
25.7
2230
3
50
Stranded, Class 2
28.5
2490
3
70
Stranded, Class 2
32.3
3290
3
95
Stranded, Class 2
37
4440
3
120
Stranded, Class 2
40.4
5470
3
150
Stranded, Class 2
45.5
6930
3
185
Stranded, Class 2
49.8
8350
3
240
Stranded, Class 2
55.1
10400
3
300
Stranded, Class 2
60.2
12600
3
400
Stranded, Class 2
66.6
14600
No. of Cores Nominal Cross-sectional Area (mm²) Conductor Type Nominal Overall Diameter (mm) Nominal Weight (kg/km)
4
1.5
Stranded, Class 2
13.3
365
4
2.5
Stranded, Class 2
15.0
438
4
4
Stranded, Class 2
16.4
532
4
6
Stranded, Class 2
18.7
764
4
10
Stranded, Class 2
21.1
1013
4
16
Stranded, Class 2
23.4
1360
4
25
Stranded, Class 2
26.1
2160
4
35
Stranded, Class 2
28.6
2690
4
50
Stranded, Class 2
32.0
3130
4
70
Stranded, Class 2
37.7
4500
4
95
Stranded, Class 2
41.7
5600
4
120
Stranded, Class 2
47.1
7400
4
150
Stranded, Class 2
51.4
8780
4
185
Stranded, Class 2
56.6
10630
4
240
Stranded, Class 2
63
13390
4
300
Stranded, Class 2
68.8
16290
4
400
Stranded, Class 2
78.1
19800
No. of Cores Nominal Cross-sectional Area (mm²) Conductor Type Nominal Overall Diameter (mm) Nominal Weight (kg/km)
5
1.5
Stranded, Class 2
14.3
410
5
2.5
Stranded, Class 2
16.1
470
5
4
Stranded, Class 2
17.8
710
5
6
Stranded, Class 2
20
876
5
10
Stranded, Class 2
22.9
1165
5
16
Stranded, Class 2
26.6
1742
5
25
Stranded, Class 2
31.5
2323
5
35
Stranded, Class 2
34.8
2932
5
50
Stranded, Class 2
40.4
4192
5
70
Stranded, Class 2
44.9
5443
5
95
Stranded, Class 2
41.3
4875
5
120
Stranded, Class 2
55.9
9026
5
150
Stranded, Class 2
61.4
10912
5
185
Stranded, Class 2
67.6
13119
5
240
Stranded, Class 2
74.8
16427
5
300
Stranded, Class 2
83.2
20915

Class 2 Stranded Copper Conductors for Single Core and Multi-Core Cables

Nominal Size Conductor Structure MAX. DC CONDUCTOR RESISTANCE AT 20°C — PLAIN ANNEALED COPPER (Ω/km)
1.5
Stranded, Class 2
12.1
2.5
Stranded, Class 2
7.41
4
Stranded, Class 2
4.61
6
Stranded, Class 2
3.08
10
Stranded, Class 2
1.83
16
Stranded, Class 2
1.15
25
Stranded, Class 2
0.727
35
Stranded, Class 2
0.524
50
Stranded, Class 2
0.387
70
Stranded, Class 2
0.268
95
Stranded, Class 2
0.193
120
Stranded, Class 2
0.153
150
Stranded, Class 2
0.124
185
Stranded, Class 2
0.0991
240
Stranded, Class 2
0.0754
300
Stranded, Class 2
0.0601
400
Stranded, Class 2
0.047

The above table is in accordance with IEC 60228

Why Choose Vastcore Cable

Project-Based Cable Configuration

Cable size, core quantity, sheath colour and construction can be selected according to project requirements and installation conditions.

Clear Technical Communication

We review cable specifications, operating conditions and required standards before quotation and production coordination.

Inspection and Documentation

Applicable test reports, inspection records, packing details and shipping documents can be prepared according to order requirements.

START YOUR PROJECT

Ready to Discuss Your Cable Requirements?

Send us your cable specifications, conductor size, core configuration, required quantity and destination. Our team will review the requirements and prepare the quotation for you.