0.6/1 kV CU/XLPE/PVC Power Cables

Copper conductor power cables with XLPE insulation and a PVC outer sheath for low-voltage power distribution. Available in multiple core configurations and conductor sizes to suit project requirements.

cu xlpe cable cable cu xlpe

0.6/1 kV CU/XLPE/PVC Power Cables Overview

0.6/1 kV CU/XLPE/PVC power cables are designed for low-voltage power distribution. They consist of copper conductors, XLPE insulation and a PVC outer sheath.

We can supply these cables with different core configurations and cross-sectional areas according to your project requirement. Share your requirements with us to check the available options.

Applications

These cables are used in low-voltage power distribution systems for buildings, industrial facilities and infrastructure projects. The suitable cable configuration depends on the installation conditions, electrical load and project requirements. These cables are suitable for low-voltage power distribution in commercial buildings, industrial facilities and infrastructure projects.

utility power distribution network with medium voltage cable installation

Power Distribution

For power distribution networds and substations.

low-voltage-power-distribution-using-PVC-power-cables_720x440

Industrial Facilities

For factories, workshops, processing plants and industrial equipment.

commercial and residential wiring projects with PVC cables

Commercial Buildings

For offices, shopping centres and other commercial building systems.

underground and outdoor power distribution cable installation

Infrastructure Projects

For transport facilities, utilities and public infrastructure projects.

CHARACTERISTICS

Voltage Rating Uo/U

0.6/1 kV

Temperature Rating

Fixed: -30°C to +90°C

Minimum Bending Radius

During Installation: 15 × overall diameter
Fixed: 10 × overall diameter

industrial electrical installation using PVC insulated cables

Cable Construction

The cable consists of a stranded copper conductor, XLPE insulation and a PVC outer sheath. Construction details can be adjusted according to project specifications and applicable standards.

Item Description
Conductor
Class 2 stranded copper conductor
Insulation
XLPE (Cross-Linked Polyethylene)
Sheath
PVC (Polyvinyl Chloride)

Cable Sizes & Technical Parameters

Nominal Size Conductor Structure Max. DC Resistance (Ω/km, 20°C) Insulation Nominal Thickness (mm) Sheath Nominal Thickness (mm) Approx. Outer Diameter (mm) Approx. Weight (kg/km)
1×1.5
Stranded, Class 2
12.1
0.7
1.5
6
61
1×2.5
Stranded, Class 2
7.41
0.7
1.5
6.5
81
1×4
Stranded, Class 2
4.61
0.7
1.5
7
107
1×6
Stranded, Class 2
3.08
0.7
1.5
7.6
131
1×10
Stranded, Class 2
1.83
0.7
1.5
8.5
181
1×16
Stranded, Class 2
1.15
0.7
1.5
9.5
247
1×25
Stranded, Class 2
0.727
0.9
1.5
11
351
1×35
Stranded, Class 2
0.524
0.9
1.5
12
448
1×50
Stranded, Class 2
0.387
1
1.5
13.5
601
1×70
Stranded, Class 2
0.268
1.1
1.5
15.5
808
1×95
Stranded, Class 2
0.193
1.1
1.5
17
1064
1×120
Stranded, Class 2
0.153
1.2
1.5
19
1305
1×150
Stranded, Class 2
0.124
1.4
1.6
22
1613
1×185
Stranded, Class 2
0.0991
1.6
2
24
1978
1×240
Stranded, Class 2
0.0754
1.7
2
26
2509
1×300
Stranded, Class 2
0.0601
1.8
2
29
3111
1×400
Stranded, Class 2
0.047
2
2.1
33
3413
Nominal Size Conductor Structure Max. DC Resistance (Ω/km, 20°C) Insulation Nominal Thickness (mm) Sheath Nominal Thickness (mm) Approx. Outer Diameter (mm) Approx. Weight (kg/km)
2×1.5
Stranded, Class 2
12.1
0.7
1.8
10
117
2×2.5
Stranded, Class 2
7.41
0.7
1.8
10.8
146
2×4
Stranded, Class 2
4.61
0.7
1.8
11.7
186
2×6
Stranded, Class 2
3.08
0.7
1.8
12.7
237
2×10
Stranded, Class 2
1.83
0.7
1.8
15.1
346
2×16
Stranded, Class 2
1.15
0.7
1.8
17.2
485
2×25
Stranded, Class 2
0.727
0.9
1.8
19.9
703
2×35
Stranded, Class 2
0.524
0.9
1.8
22
916
2×50
Stranded, Class 2
0.387
1
1.8
20.4
1149
2×70
Stranded, Class 2
0.268
1.1
1.8
23.1
1554
2×95
Stranded, Class 2
0.193
1.1
1.8
25.5
2040
2×120
Stranded, Class 2
0.153
1.2
1.9
28.1
2545
2×150
Stranded, Class 2
0.124
1.4
2
31.3
3168
2×185
Stranded, Class 2
0.0991
1.6
2.1
34.6
3891
2×240
Stranded, Class 2
0.0754
1.7
2.2
34.6
4985
2×300
Stranded, Class 2
0.0601
1.8
2.3
42.7
6270
2×400
Stranded, Class 2
0.047
2
2.5
48.4
8235
Nominal Size Conductor Structure Max. DC Resistance (Ω/km, 20°C) Insulation Nominal Thickness (mm) Sheath Nominal Thickness (mm) Approx. Outer Diameter (mm) Approx. Weight (kg/km)
3×1.5
Stranded, Class 2
12.1
0.7
1.8
10.4
138
3×2.5
Stranded, Class 2
7.41
0.7
1.8
11.3
177
3×4
Stranded, Class 2
4.61
0.7
1.8
12.3
232
3×6
Stranded, Class 2
3.08
0.7
1.8
13.4
303
3×10
Stranded, Class 2
1.83
0.7
1.8
16
452
3×16
Stranded, Class 2
1.15
0.7
1.8
18.2
646
3×25
Stranded, Class 2
0.727
0.9
1.8
21.1
953
3×35
Stranded, Class 2
0.524
0.9
1.8
23.4
1256
3×50
Stranded, Class 2
0.387
1
1.8
23.6
1657
3×70
Stranded, Class 2
0.268
1.1
1.8
26.8
2258
3×95
Stranded, Class 2
0.193
1.1
1.9
30.2
2997
3×120
Stranded, Class 2
0.153
1.2
2
33.2
3748
3×150
Stranded, Class 2
0.124
1.4
2.2
37.2
4674
3×185
Stranded, Class 2
0.0991
1.6
2.3
42.3
5777
3×240
Stranded, Class 2
0.0754
1.7
2.5
47.2
7412
3×300
Stranded, Class 2
0.0601
1.8
2.6
51.9
9318
3×400
Stranded, Class 2
0.047
2
2.8
57.7
12208
Nominal Size Conductor Structure Max. DC Resistance (Ω/km, 20°C) Insulation Nominal Thickness (mm) Sheath Nominal Thickness (mm) Approx. Outer Diameter (mm) Approx. Weight (kg/km)
4×1.5
Stranded, Class 2
12.1
0.7
1.8
12.1
164
4×2.5
Stranded, Class 2
7.41
0.7
1.8
12.1
214
4×4
Stranded, Class 2
4.61
0.7
1.8
13.3
285
4×6
Stranded, Class 2
3.08
0.7
1.8
14.9
376
4×10
Stranded, Class 2
1.83
0.7
1.8
17.4
568
4×16
Stranded, Class 2
1.15
0.7
1.8
19.9
821
4×25
Stranded, Class 2
0.727
0.9
1.8
23.2
1222
4×35
Stranded, Class 2
0.524
0.9
1.8
25.8
1620
4×50
Stranded, Class 2
0.387
1
1.8
26.2
2163
4×70
Stranded, Class 2
0.268
1.1
1.8
30
2971
4×95
Stranded, Class 2
0.193
1.1
2.1
34.5
3965
4×120
Stranded, Class 2
0.153
1.2
2.2
37.6
4951
4×150
Stranded, Class 2
0.124
1.4
2.3
42.5
6190
4×185
Stranded, Class 2
0.0991
1.6
2.5
46.7
7605
4×240
Stranded, Class 2
0.0754
1.7
2.6
52.5
9769
4×300
Stranded, Class 2
0.0601
1.8
2.9
59.3
12359
4×400
Stranded, Class 2
0.047
2
3.1
67.5
16264
Nominal Size Conductor Structure Max. DC Resistance (Ω/km, 20°C) Insulation Nominal Thickness (mm) Sheath Nominal Thickness (mm) Approx. Outer Diameter (mm) Approx. Weight (kg/km)
5×1.5
Stranded, Class 2
12.1
0.7
1.8
11.9
190
5×2.5
Stranded, Class 2
7.41
0.7
1.8
13
252
5×4
Stranded, Class 2
4.61
0.7
1.8
14.5
341
5×6
Stranded, Class 2
3.08
0.7
1.8
15.9
454
5×10
Stranded, Class 2
1.83
0.7
1.8
19.3
690
5×16
Stranded, Class 2
1.15
0.7
1.8
22.1
1004
5×25
Stranded, Class 2
0.727
0.9
1.8
25.7
1498
5×35
Stranded, Class 2
0.524
0.9
1.9
28.9
2005
5×50
Stranded, Class 2
0.387
1
1.9
29.1
2685
5×70
Stranded, Class 2
0.268
1.1
2
33.4
3694
5×95
Stranded, Class 2
0.193
1.1
2.2
37.4
4910
5×120
Stranded, Class 2
0.153
1.2
2.3
42.6
6192
5×150
Stranded, Class 2
0.124
1.4
2.5
47.6
7728
5×185
Stranded, Class 2
0.0991
1.6
2.7
52.8
9515
5×240
Stranded, Class 2
0.0754
1.7
2.9
59
12225
1×300
Stranded, Class 2
0.0601
1.8
3.1
65.5
15413
5×400
Stranded, Class 2
0.047
2
3.4
74.5
20291
Nominal Size Conductor Structure Max. DC Resistance (Ω/km, 20°C) Insulation Nominal Thickness (mm) Sheath Nominal Thickness (mm) Approx. Outer Diameter (mm) Approx. Weight (kg/km)
3×10+1×6
Stranded, Class 2
1.83/3.08
0.7/0.7
1.8
16.8
522
3×16+1×10
Stranded, Class 2
1.15/1.83
0.7/0.7
1.8
19.3
758
3×25+1×16
Stranded, Class 2
0.727/1.15
0.9/0.7
1.8
22.4
1122
3×35+1×16
Stranded, Class 2
0.524/1.15
0.9/0.7
1.8
24.2
1414
3×50+1×25
Stranded, Class 2
0.387/0.727
1/0.9
1.8
26.1
1936
3×70+1×35
Stranded, Class 2
0.268/0.524
1.1/0.9
1.9
30
2648
3×95+1×50
Stranded, Class 2
0.193/0.387
1.1/1
2.1
34.5
3554
3×120+1×70
Stranded, Class 2
0.153/0.268
1.2/1.1
2.2
37.6
4495
3×150+1×70
Stranded, Class 2
0.124/0.268
1.4/1.1
2.3
42.5
5448
3×185+1×95
Stranded, Class 2
0.0991/0.193
1.6/1.1
2.5
46.7
6760
3×240+1×120
Stranded, Class 2
0.0754/0.153
1.7/1.2
2.6
52.2
8647
3×300+1×150
Stranded, Class 2
0.0601/0.124
1.8/1.4
2.9
59.3
10917
3×400+1×185
Stranded, Class 2
0.047/0.0991
2/1.6
3.1
67.5
14232
Nominal Size Conductor Structure Max. DC Resistance (Ω/km, 20°C) Insulation Nominal Thickness (mm) Sheath Nominal Thickness (mm) Approx. Outer Diameter (mm) Approx. Weight (kg/km)
3×10+2×6
Stranded, Class 2
1.83/3.08
0.7/0.7
1.8
17.9
598
3×16+2×10
Stranded, Class 2
1.15/1.83
0.7/0.7
1.8
21
880
3×25+1×16
Stranded, Class 2
0.727/1.15
0.9/0.7
1.8
24.3
1304
3×35+2×16
Stranded, Class 2
0.524/1.15
0.9/0.7
1.8
25.7
1598
3×50+2×25
Stranded, Class 2
0.387/0.727
1/0.9
1.8
27.8
2201
3×70+2×35
Stranded, Class 2
0.268/0.524
1.1/0.9
2
31.8
3010
3×95+2×50
Stranded, Class 2
0.193/0.387
1.1/1
2.1
35.6
4042
3×120+2×70
Stranded, Class 2
0.153/0.268
1.2/1.1
2.2
39.6
5187
3×150+2×70
Stranded, Class 2
0.124/0.268
1.4/1.1
2.3
43.2
6121
3×185+2×95
Stranded, Class 2
0.0991/0.193
1.6/1.1
2.5
48.5
7693
3×240+2×120
Stranded, Class 2
0.0754/0.153
1.7/1.2
2.7
53.5
9807
3×300+2×150
Stranded, Class 2
0.0601/0.124
1.8/1.4
2.9
59.9
12347
3×400+2×185
Stranded, Class 2
0.047/0.0991
2/1.6
3.2
67.9
16003
Nominal Size Conductor Structure Max. DC Resistance (Ω/km, 20°C) Insulation Nominal Thickness (mm) Sheath Nominal Thickness (mm) Approx. Outer Diameter (mm) Approx. Weight (kg/km)
4×10+1×6
Stranded, Class 2
1.83/3.08
0.7/0.7
1.8
18.6
646
4×16+1×10
Stranded, Class 2
1.15/1.83
0.7/0.7
1.8
21.5
944
4×25+1×16
Stranded, Class 2
0.727/1.15
0.9/0.7
1.8
25
1401
4×35+1×16
Stranded, Class 2
0.524/1.15
0.9/0.7
1.8
27.4
1809
4×50+1×25
Stranded, Class 2
0.387/0.727
1/0.9
1.8
28.2
2430
4×70+1×35
Stranded, Class 2
0.268/0.524
1.1/0.9
2
32.3
3337
4×95+1×50
Stranded, Class 2
0.193/0.387
1.1/1
2.1
36.6
4466
4×120+1×70
Stranded, Class 2
0.153/0.268
1.2/1.1
2.3
40.8
5660
4×150+1×70
Stranded, Class 2
0.124/0.268
1.4/1.1
2.4
45
6900
4×185+1×95
Stranded, Class 2
0.0991/0.193
1.6/1.1
2.6
50.6
8588
4×240+1×120
Stranded, Class 2
0.0754/0.153
1.7/1.2
2.8
56.5
11006
4×300+1×150
Stranded, Class 2
0.0601/0.124
1.8/1.4
3
62.7
13859
4×400+1×185
Stranded, Class 2
0.047/0.0991
2/1.6
3.3
70.9
18110

Why Choose Vastcore Cable

Project-Based Configuration

We supply cable configurations based on your required voltage, conductor material, core arrangement and installation conditions.

Clear Technical Communication

We review your cable specifications and project requirements with you, helping clarify construction details before quotation and production.

Responsive Technical Support

Share your cable specifications and application details with our team. We’ll review the requirements and help you identify a suitable option.

START YOUR PROJECT

Ready to Discuss Your Cable Requirements?

Send us your cable specifications, required quantity and destination. Our team will review the manufacturing requirements and prepare the next step for quotation.